TechRepublic : A ZDNet Tech Community

10 things you should know about deploying technology in harsh environments

Tags: Servers, Rick Vanover, enclosure, air conditioner

  • Save
  • Print
  • Recommend
  • 1

Takeaway: When you put technology assets into an unfriendly environment, the lifecycle of your equipment may be cut in half. Fortunately, you can take steps to help preserve it, along with simplifying maintenance, operations, and support.

This article is also available as a PDF download.

If you've ever had to put a computer in a shop environment, you know that its lifecycle may be shortened--even halved--by exposure to high temperatures, moisture, air particulate, or other irritants to electronics. Here are some lessons learned from deploying technology to harsh environments that will help you maintain the IT equipment lifecycle in the worst of conditions.

#1: Solutions for visibility and security


As many members will attest, having good visibility is key to being able to support a critical piece of equipment that's outside the data center--and possibly at a location that has no IT staff. This goes for harsh environments as well. Products today offer many solutions to ensure both visibility and security so that operators (and anyone else) can see "the red light" on the server or whatever is deployed. For example, Figure A shows a server system pair in an enclosure.

Figure A

From outside the enclosure, you can:

  • See which server is powered on (with this equipment, green is on, amber is off).
  • See which hard drives are spinning (green is running, black is off, red is failed).
  • See the blue UID (unit identifier) light on the server (a handy feature of ProLiant servers).
  • Determine whether the external hard drive array (top) is spinning all drives.

This enclosure has a lockable front panel to keep unwanted users out. Note that the batteries are outside the enclosure. In this case, this was done to reduce the exhaust inside the enclosure.

If you choose this option, bear in mind that you may or may not be able to fully support the system entirely remotely.

#2: Selecting an enclosure and air conditioner


This market has many offerings covering a range of quality, features, and price. When deciding on an enclosure, make sure you can accurately calculate:

  • Interior dimensions
  • Weight capacity and overall weight
  • Ergonomic considerations
  • Cable entry/exit accessibility

Most enclosures allow you obtain detailed technical information. Figure B shows an ITS Enclosures ICEStation 7219 rack enclosure. ITS Enclosures offers good technical information for your planning phase.

Figure B

You may need to deploy an air conditioner with the enclosure, and most providers will help you select the correctly powered air conditioner for the system you're implementing, sell you the unit, and attach it to the enclosure. Be sure not to under-provision a system in cooling management from the start. Thermal overloads in your integrated management logs are not pleasant.

Most, if not all, enclosure air conditioners detail their information on the exterior in a visible manner, as shown in Figure C.

Figure C

This label indicates that the air conditioner can operate between 3800 and 4000 BTU for thermal cooling. The power requirements and thermal ranges are also detailed.

A good rule of thumb is to add approximately 35 percent utilization to your base BTU requirement to ensure adequate thermal provisioning. Also consider using TFT screens instead of CRT monitors for less thermal strain on the interior (unlike our photo examples).

#3: Power provisioning


Although most IT staffers are familiar with getting basic power service in the data center, getting selected power in other locations brings new challenges. When working with non-data center locations, be sure that you clearly communicate the power requirements with the following traits:

  • Provide quantity and connection type requirements (e.g., QTY 2 NEMA L5-30P would be the "30 Amp Twist Lock" that is used by many UPS units).
  • Provide a picture of the connection type--you can obtain this from the technical information of all products you're feeding.
  • Request separate circuits for your power protection (UPS) and air conditioner unit.
  • Know the input voltage requirements.

#4: Drainage for thermal management


This may be peculiar topic, but many air conditioners rely on standard evaporation from a small tray for the liquid discharge that it pulls from the interior air. As the air becomes more conditioned, less humidity will come from the interior, but there's still a drainage factor. Drainage can't be ignored, especially if there's frequent access to the inside of the enclosure.

Two basic options are available:

  • A heated metal plate that causes instant evaporation of the drip condensations
  • A bucket and flex tubing

The bucket and flex tubing may sound unsophisticated, but it's a $10 solution that's quite manageable, and it doesn't take much effort to install. The heated plates require additional power, and installation is not at all pleasant.

#5: Planning for accessibility


Just like in the data room, where you can extend a server out of a rack, you should be able to do the same from the enclosure in the remote environment. Many full specification rack enclosures allow you to mount standard servers and fully extend forward. This makes installation and serviceability much easier. You can also likely utilize cable management arms in these types of enclosures.

#6: Ensuring phone line proximity


All IT staffers surely have access to a mobile phone, but it's still a good idea to have a telephone line close to the remote enclosure. Support is much easier for operational staff (who may not have mobile phones), as well as vendors who may be collaborating on the remote technology in the enclosure. Regardless of the user, having a phone line accessible, or even in the cabinet, can greatly reduce the time to identify and communicate a potential issue, as well as increasing possible operational benefits. A phone line also has a possible use as a contingency modem if the network link to this station fails.

#7: Dealing with extreme cold


This may sound like a thermal management nonissue, right? Think again. Having deployed technology solutions in freezer areas of food distribution centers, I've learned that you may not be able to rely on the exhaust of a system to provide adequate heat. For example, most technology equipment's operating temperature range is 50 degrees F on the bottom end. This is a far cry from the -40 degree F environments in a large freezer complex. While operating, a device may make enough exhaust heat to keep it in the operating range. However during storage or idle times, you run the risk of damaging the components and possibly voiding the warranty, as ice may form on the inside of the components.

Just as air conditioners can keep enclosures cool, thermal management heating solutions can keep an enclosure in an operating range for equipment. Be sure to get one with thermostat-like control because if the ambient temperature gets within a tolerable range, you want the heating source to idle so it won't overheat the interior. This is especially important if you deploy a solution that uses an cold, or idle, secondary system.

#8: Facilitating support by nontechnical staff


Visibility and labeling are important for technology deployed in harsh environments. You may not have IT staff working with the system, and certain operational and troubleshooting elements may be done by facility maintenance staff, operational staff, managers, or other non-IT individuals.

For example, take the rack shown in Figure D, which a TechRepublic member recently implemented for a customer solution. The rack uses intuitive connectivity and labeling as follows:

  • Red cables are Ethernet networking cables going to a local switch.
  • Gray cables are special long-haul serial lines going to an Ethernet-attached multiport serial adapter (not connected in the image).
  • Each cable end is labeled for its role.
  • A label panel on the cable management identifies each network port.
  • Cable management flex conduit keeps like cables together and run snug through the enclosure.

Figure D

#9: Preventive maintenance on the air conditioner


If your enclosure has an air conditioner with a replaceable air filter, be sure to replace it. These are not expensive pieces but are critical to the effective operation of the air conditioner in filtering airborne particulate from entering the controlled environment inside the enclosure.

The other important preventative maintenance task is to ensure that the air conditioner has adequate Freon. A common strategy is to make a facility maintenance staff responsible for replacing the air filters and keeping the Freon charged.

#10: Consolidated technology spots


Many factories, shops, and distribution centers have networking cabinets/enclosures on the floor to extend the network infrastructure for the technology elements. These enclosures are generally not in environmentally controlled enclosures. If you deploy larger systems (e.g., servers or critical workstations) in a harsh environment and have a full size enclosure, consider consolidating the network infrastructure into the same enclosure for a smaller IT footprint and consolidated enclosure space.

  • Save
  • Print
  • Recommend
  • 1

Print/View all Posts Comments on this article

10 things you should know about deploying technology in harsh environments JodyGilbertTechrepublic Moderator | 05/05/06
Overblown problem Palmetto | 05/05/06
RE: Overblown problem b4real@... | 05/07/06
The worst?? mjd420nova | 05/05/06
Acid bath Dr Dij | 05/05/06
RE: Acid bath b4real@... | 05/07/06
PCs like environmental consistency better ideallypc | 05/09/06
Paper plants were tought... stephenmoriarty@... | 05/09/06
RE: PCs like environmental consistency better b4real@... | 05/10/06
that environment Jaqui | 02/12/08
Dusty PC TheOnlyRick | 02/12/08

What do you think?

White Papers, Webcasts, and Downloads

Article Categories

Security
Security Solutions, IT Locksmith
Networking and Communications
E-mail Administration NetNote, Cisco Routers and Switches
CIO and IT Management
Project Management, CIO Issues, Strategies that Scale
Desktops, Laptops & OS
Windows 2000 Professional, Microsoft Word, Microsoft Excel, Microsoft Access, Windows XP,
Data Management
Oracle, SQL Server
Servers
Windows NT, Linux NetNote, Windows Server 2003
Career Development
Geek Trivia
Software/Web Development
Web Development Zone, Visual Basic, .NET

SmartPlanet

Click Here